You asked: Can you have electrical wiring behind a shower wall?

Can plumbing and electrical be in the same wall?

Plumbing and electrical in the same wall cavity are fine, even if they do touch. Remember, all electrical is insulated. Bare ground wires are OK too.

How close can an electrical panel be to a shower?

You should keep the receptacle at least 6 feet away from the edge of a bathtub or shower and at least 1 foot away from sinks. Avoid positioning a receptacle over the center of the sink, where cords hairdryers and electric shavers might hang down into the basin.

How do you know if there is electrical behind drywall?

According to Popular Mechanics, the best tool for locating wires is a stud finder with AC wire detection. Use painters’ tape around the area you wish to scan; this will serve as a place to mark the location of the wires after detection.

Can I bury water line and electric together?

If trench is to be a joint trench (shared with other utilities) the following separations must be maintained: 24 inches between gas and electric lines. 12 inches between water and electric lines. … 12 inches between communications and electric lines.

GOOD TO KNOW:  How many coal power plants did China build last year?

Is it OK to zip tie electrical wires together?

However, for an electrical panel or in a conduit, zip ties or Velcro strips can be dangerous. The nylon harness is a good way to keep wire and cable bundled together neatly, efficiently, and effectively. … The binder is less likely to damage the wire or cables.

Can you put an electrical panel in a laundry room?

According to the Meriwether Lewis Electric Cooperative, electrical panels must have an open space 30 inches wide and 36 inches deep for overall electrical and fire safety. These panels can be placed in a laundry room, as long as appliances and piping do not infiltrate the open space rule.

How far does a water line have to be from an electrical panel?

You need to have a clear working space 30 inches wide and 36 inches deep in front of the panel (42 inches deep if there are grounded parts on the back side of the space – this includes concrete walls, metal pipes, etc.) As long as the sink is outside that space you should be fine.

Can an electric panel be in the bathroom?

An electrical panel containing the service disconnecting means cannot be located in a bathroom [230.70(A)(2)]. In dwelling units and guest rooms or suites of hotels and motels, overcurrent devices cannot be located in bathrooms [240.24(E)].

Where can you not drill into walls?

Avoid drilling near light sockets or outlets

Wires in the wall often connect vertically and horizontally behind outlets and sockets and can lead to electrocution. Hitting a pipe in the wall can cause flooding. A simple rule of thumb is to avoid drilling anywhere near where there may be electrical hookups or piping.

GOOD TO KNOW:  Frequent question: Who owns Fukushima nuclear plant?

Can you drill anywhere in a wall?

One rule of thumb is to be especially careful when drilling into any walls that connect to your bathroom or kitchen—basically, any wall that’s likely to have pipes. … “And unless you hit it where it passes through a stud, your drill bit will probably deflect off of the curved surface.”